90L055KP1NN80P3S1C03GBA262624 hydraulic pump
90L055KP1NN80P3S1C03GBA262624 hydraulic pump
- Product Details
- Applicable Scene
Danfoss hydraulic pumps are known for their reliability and efficiency in a range of applications. However, like all mechanical systems, they can encounter issues over time, and one common problem is excessive vibration. Diagnosing vibration problems in these pumps is crucial for maintaining operational efficiency and preventing costly failures. This article will explore the causes of vibration in Danfoss hydraulic pumps and outline steps for effective diagnosis and resolution.
90-L-055-KP-1-NN-80-P-3-S1-C-03-GBA-26-26-24
90L055KP1NN80P3S1C03GBA262624
Vibration in hydraulic pumps can stem from various factors, each requiring careful analysis to identify the root cause. Some of the most common causes include:

80002025C
Misalignment: One of the leading causes of vibration is misalignment between the pump and its driver, whether it be an electric motor or another power source. Misalignment can lead to uneven wear and stress on the pump components.
Imbalance: An unbalanced rotor or rotating assembly can create excess vibration. This might occur due to the accumulation of debris, wear and tear, or manufacturing defects that affect the rotor’s symmetry.
Wear and Tear: Over time, internal components of the pump, such as bearings, gears, and seals, can wear down. This wear can lead to increased clearances and reduced efficiency, resulting in vibrations as the components no longer fit together perfectly.
Cavitation: Cavitation occurs when vapor bubbles form in the fluid and collapse violently, creating shock waves that can lead to vibration. It typically arises from low inlet pressure or high flow rates.
Hydraulic Imbalances: Variations in hydraulic fluid flow or pressure can cause imbalances that manifest as vibration. This may be due to blockages, changes in fluid viscosity, or issues in the overall hydraulic system.
Steps for Diagnosing Vibration Problems
To effectively diagnose and address vibration issues in Danfoss hydraulic pumps, follow these steps: